SIMPLEX 4007ES FIRE ALARM CONTROL PANEL


Simplex fire alarm solutions are trusted the world over, helping protect millions of people every day in large facilities that range from hospitals, hotels and universities to airports, office buildings and sky scrapers. Customers choose our products for their industry-leading scalability, reliability, long-term value and technology.

The Simplex 4007ES brings big-panel advantages to smaller facilities, offering advanced features that include TrueAlert ES addressable technology and a color touchscreen display.

With a streamlined design, compact footprint, and unprecedented flexibility for a small panel, the Simplex 4007ES is a powerful solution for a wide variety of projects:

SchoolsSmall-to mid-size office buildingsLibrariesRetail shopsSmall healthcare facilities
We’ve packed many of the advanced features you’d find in our larger panels into a compact, cost- effective package, making it a great solution for smaller facilities.

Easy touchscreen operation
With a 4.3” (10.9 cm) color touch screen display and intuitive, menu-driven interface, the Simplex 4007ES is remarkably easy to use. You can quickly access detailed information, view reports, and perform a variety of operations.

Smooth installation
Fully addressable Simplex 4007ES panels integrate seamlessly with addressable devices and appliances, while offering a flexible wiring infrastructure that makes installation faster, easier, and more cost effective. The Simplex 4007ES Hybrid panel is compatible with both addressable and conventional initiating devices, so it’s ideal for retrofit and expansion projects. This model also makes the use of existing wiring much easier through its compatibility with shielded or unshielded and twisted or untwisted wire (12 – 18 AWG). In addition, the Simplex 4007ES has programmable end of line resistor compatibility which allows you to use the existing wiring infrastructure without having to find and replace the end of line resistors that are already installed.

The Power of TrueAlert ES Technology

More Information please visit https://simplex-fire.com/en/us/Pages/ProductSeries.aspx?ProductType=Control+Panels



Tuesday, May 19, 2015

Thorn Addressable Control Panel MZX250 Single Loop, Fire Detection system 250 Addresses, 32 Zones




Features: Fire Alarm Detection Systems
  • Long term service and support
  • Two way IR communications with Generation 6 Detectors reduces commissioning and service costs.
  • Deep housing with capacity for up to 38AH batteries (MZX251 / MZX252 / MZX254 only)
  • 2 KM loop length
  • 32 way zonal LED display (MZX250 / MZX251 / MZX252 only)
  • 240 Zones capability - No zonal display (MZX254 only)
  • High level User Interface with “Front Panel Controls” to reduce lifetime cost of ownership
  • Wide range of multi-sensor detectors including the 3oTec triple sensing detectors. Early detection without false alarms.
  • Wide range of ancillaries including door control to BS7273 category A
  • Matching fully functional mains and 24vdc powered repeaters available
  • DDA compliance using the advanced 3000 series AV Base and loop powered sounder beacons.
  • Approved to EN54 the system is designed to be installed to BS5839




Technical Specifications

Minerva MZX252 Control Panel & Repeater

Mechanical

Dimensions (mm): H W D

Panel                         480 x 410 x 205mm

Repeater                    480 x 410 x 140mm

Approx Weight:

Panel                         10.6Kg

Repeater                    9.3Kg

Colour

Housings:                   RAL 7035

Control Facia:              Pantone Grey 431C

Environmental

Operating Temperature: -8OC to +55OC Storage Temperature: -20OC to +70OC

Relative Humidity: 90% RH continuous (non-condensing)

EMC/RFI:

EN50130-4, EN50081-1

Electrical


Supply Voltage:
230VAC 50/60 Hz
Input Current (panel)
1.6A

The Minerva® MZX252 is a highly featured digital addressable panel with a comprehensive
but easy to operate user interface. The system provides two loops, each with 250 addresses making
it suitable for medium size premises.

The MXDigital protocol is robust enough to operate over most cable types making it an ideal choice for upgrades where existing cables can be reused to dramatically cut costs. The built in power supply will charge the internal batteries and support a full compliment of loop powered sounders and beacons in accordance with the requirements of BS5839. The Minerva® MZX252 is a fire detection controller at the heart of a comprehensive fire detection system that can be used to protect both life and property.

A matching 32 zone fully functional repeater is available, A maximum of 7 repeaters can be driven from the control panels 2 wire remote bus, the repeater houses its own mains psu and batteries.

Download The Minerva® MZX252 data sheet from Fire Alarm Manufactures



Morley-IAS DX Connexion panel , Fire Detection System Addressable up to 16 Loop



Product Overview

The Morley-IAS DX Connexion panel was ideally designed for use in the
construction area protection projects. In general, it is a fire control
panel with highly cost-effective, compact, with many functions, high
performance, designed to help both the installer and the end user.

The DX Connexion is an improvement of the Morley-IAS Dimension panels
line, combining traditional reliability, flexibility and value of

Morley-IAS panels to new advanced features and intuitive operation.

The line DX Connexion fire alarm control panels was developed in order
to provide the panel with the largest market installation time
efficiency. You simply need to fix the wall to the control panel,
connect wiring of field devices, and through a guided programming 4
steps, will have an efficient fire alarm system in place.

The dimensions of the panel graphical display provides a clear menu
structure making all fast boot process, simple and intuitive.

The control panel programming could not be easier. The texts to
identify the exact location of each field device can be quickly entered
via the front keypad. Alternatively, the text can be entered or
imported from a document in Excel format, using the configuration tool
DX Connexion.

All panel functions and system operating logic can be programmed in the
control panel itself or using the configuration tool executable under
Windows.

Network Features
- Network with up to 16 loops (16 lace panels 1, 2 of 8 panels ties,
four panels 4 loops or any combination of panels up to 16 links)
- Network point-to-point (event sharing and commands) with the same
priority and tolerant to high system reliability

Control panel
- 99 sensors + 99 modules per line detection
- Programming guided through four steps
- Graphical display of 6x40 characters (240x64 pixels) with
customizable logo
- USB programming interface for upload / download configuration
- Fully configurable via the keyboard

Software Functions
- Configuration tool DX Connexion (supplied with the panel)
- Fire zones 80 and 40 shooting programs
- 14 scheduling modes
- 1000 events History and diagnostic option records
- False alarm management for verification and coincidence detection
- Equipment sensitivity adjustment time
- Logic programming of inputs and outputs

- Portuguese Language

Wednesday, September 17, 2014

Cross Zone for Releasing Control Panel?



Our customer have question about cross zone detector below question.

 When one of smoke detector has detector smoke fire alarm panel will show Alert (LED Indication on Fire alarm control panel or releasing control panel after that another flame detector has detector Flame so on fire alarm control panel will show alarm (LED indicator on the panel), Our customer would like to know about Alarm will show both for Alert LED and Alarm LED or show alarm on Alarm LED only.


Cross zone is a check or inspection requirements for the two detectors in sequence before activating the alarm modelThe smoke detector alarm so as to be sensitive to environmental factors such as dust and impurities that cause false alarms, it is for this reason that leave to cross the zone has been the industry standard when involved in fire suppression systems, automatic actuation of smoke, such as fire prevention actions ahead of time, or a good agent. However, many fire suppression system owners don't understand the installation and program optionsto one of several detection methods, compared to.


General detection zone crossing technique involves two different methods are used to detect smoke with a separate zone. The advantage of this method is that there is more margin light before release instead of Communists. The table below lists verified across the zone several 
inspection methods. Below is flow chart for cross zone detector .








More detail for Autopluse fire detection system on youtube

Thursday, September 20, 2012

Simplex Anunciator Panel Problem 4605-7401

Our client has requested for make local mimic graphic panel size A3 so we select simplex part number 4605-7401 24 I/O anunciator module that we think can connect with Simplex 4008 ,one loop addressable fire alarm control panel but the problem is we can not connect 4605-7401 with Simplex model 4008 addressable fire alarm control panel. So this model suitable with Simplex addressable fire alarm control panel model 4010ES or 4010 that more capability than 4008.

Wednesday, July 18, 2012

SIMPLEX 4008 Fire Alarm Control Panel Addressable


Feature for Truealarm Addressable Fire Alarm Control Panels

Brand :SIMPLEX
Approved : UL,ULC,CSFM, FM Approved
Product Onwer by TYCO
  • 2 LCD Display, 2x 20 (40 Character) and LED for show the status information.
  • Operationg by keypad and the panel LCD or via personel computer(PC),
  • Upload/download PC pass RS232 for panel configuration and hevent istory log.
  • INPUT
  • Addresssble Device : can connect to up to 200 addressable True Aalrm detection points or addressable device point by using IDNet Commucation.
  • OUTPUT
  • Two NACs (Standard Notification Appliance Circuit)  Class A or Class B output with solid dtate overcurrent protection per NAC each rated for 2 A.
  • Selectale for SIMPLEX SmartSync two wire horn/strobe control or synchronized  strobe control.
  • Standard Power Supply
  • Provide 3 A maximum @ nominal 24 DC
  • Automatic input power selection operates with 120 VAC or 240VAC, 50 or 60 Hz.
  • Battery charger for up to 12.7Ah battries in cabinet(UL and ULC) and UP TO 25 Ah bateries in seperate cabinet(UL only).
  • Additional Standard Feature:
  • Two Auxiliary relays
  • NCAs, Relay output and communiccation circuit and power limited.
  • Avaliable color are red and beige.
  • UL Listed to standard 864.

More detail 4008 fire detection system on youtube